Free toolbox talk · Electrocution · 10 min

Temporary Lighting Safety

Construction · Ver en español

Talking points

  1. Temporary string lights must be guarded with cages or equivalent protection to prevent accidental breakage. Bare bulbs in construction areas are a fire and shock hazard if broken.
  2. Temporary lights that plug into site receptacles are on GFCI-protected circuits — OSHA requires GFCIs on those outlets — and portable lights in wet or conductive spaces must run at 12 volts or behind a GFCI. Water, dust, and damage to wiring are common on construction sites and increase shock risk.
  3. Suspend temporary lights on insulators — do not hang them from nails, pipes, or electrical conduit. Metal supports can energize if a wire is damaged.
  4. Use lamps rated for wet or damp locations in areas exposed to weather or moisture. Indoor-rated fixtures deteriorate rapidly in construction environments.
  5. Maintain minimum illumination levels: 5 foot-candles for general construction areas, 10 foot-candles for shops, and 3 foot-candles for walkways and stairs.

Ask the crew

Are all of our temporary lights guarded, GFCI-protected, and properly suspended?

Standards this talk is built on

A toolbox talk is a short safety briefing. It supports the training a standard requires; it does not replace it.

Run this talk with your crew and keep the record

In Jobsite, workers sign in on their phones in English or Spanish, and you keep who attended, when, and where, with every other talk your crew has had.

Using an AI assistant? Jobsite's free MCP server serves this library, with OSHA rule text, no sign-in: https://jobsitecerts.com/api/mcp/public (/mcp)

Sign-in sheet

Print this page to collect signatures, or run the talk in Jobsite and workers sign in on their phones.

NameSignatureDate

© Jobsite. Free to read aloud, print and use in your own crew's safety meetings. Republishing, reselling or bulk-copying these talks is not permitted.